pop up

#partnerPopup { position: fixed; top: 20%; left: 50%; transform: translateX(-50%); background-color: #3559A0; color: white; padding: 30px 20px; border-radius: 10px; box-shadow: 0 0 10px rgba(0,0,0,0.3); z-index: 9999; text-align: center; display: none; } #partnerPopup a { background-color: white; color: #3559A0; padding: 10px 20px; border-radius: 5px; text-decoration: none; font-weight: bold; } #partnerPopup p { margin-top: 10px; font-size: 14px; } #partnerPopup span { position: absolute; top: 10px; right: 15px; cursor: pointer; font-size: 18px; }
Title Image

Shop

IABP Pumps and Consumables

Description

Overview

The AC3 Range™ Intra-Aortic Balloon Pump (IABP) from
Teleflex is an advanced mechanical circulatory support system
designed to provide temporary cardiac assistance in patients with compromised
heart function. Leveraging the award-winning design and patented technology of
the AC3 Optimus™ IABP, the AC3 Range™ delivers reliable hemodynamic support in a
compact, fully contained, and transport-ready platform. It enhances coronary
perfusion and reduces cardiac workload, supporting improved clinical outcomes
in critical cardiac care settings.

Key Features

  • Fully integrated, lightweight, and transport-ready IABP system

  • Patented balloon timing and control technology for precise counterpulsation

  • Supports both ECG and arterial pressure trigger modes

  • Automatic timing adjustments for consistent therapy delivery

  • Battery-powered operation for uninterrupted support during patient transport

  • User-friendly interface with clear visual and audible alerts

Safety & Performance

  • Continuous monitoring of balloon inflation and deflation timing

  • Automatic alarms for timing errors, pressure abnormalities, and system faults

  • Fail-safe operation to maintain therapy consistency during power interruptions

  • Reliable performance during patient transport and inter-department transfers

  • Designed to meet clinical safety standards for critical cardiac care

Clinical Applications

  • Cardiogenic shock management

  • Acute myocardial infarction with hemodynamic instability

  • Support during high-risk percutaneous coronary interventions (PCI)

  • Pre- and post-cardiac surgery circulatory support

  • Bridge therapy to definitive cardiac intervention

Clinical Benefits

  • Improves coronary artery perfusion

  • Reduces left ventricular workload and myocardial oxygen demand

  • Enables rapid deployment in emergency and transport scenarios

  • Supports clinician confidence with reliable, automated operation